Leaking Douglasville Water Heater Pressure Relief Valve

Posted by on Dec 9, 2014 in Gas Water Heater Repair Douglasville GA, Water Heater Repair Douglasville GA | 0 comments

The pressure relief valve of a water heater has an essential task – making certain the water heater tank does not explode. So with that in mind, Water Heater Repair Douglasville GA wishes to make sure homeowners know ways to best care for it. They will certainly leak when the valve wears out or when the water storage tank pressure gets greater then the relief point.Hot Water Heater Repair Douglasville GA

We suggest that a minimum of twice a year, property owners test to make sure the pressure relief valve, or T&P valve as we will call it, is working effectively. All one needs to do is raise the manage for a few seconds and let go of it. It needs to snap back to its original position. When it is raised, one may hear the sound of pressure being released , similar to the noise of air coming out of a tire pump when being disconnected. Also, a little water may come out too. Both are normal. If the valve has not been tested for a number of years, it may stick at first too.

Nevertheless, if the handle doesn’t snap back, or if it remains to leak a little water, that is not typical. If it still leaks some, raise the handle a few more times to see if it will re-seat itself. You may want to wait a day or so it see if it re-seats itself prior to assuming it needs to be changed.

Water Heater Repair Douglasville GA would like to manage any T&P valve replacements for you, so though water heaters are normally fairly maintenance free, there are some safety preventative measures one should be mindful of. With that in mind here is an introduction of a pressure relief valve replacement.

1. The gas to the water heater needs to be shut off, or the breaker for an electrical water heater.
2. The cold water cut-off valve has to be closed next.
3. The valve below the T&P valve needs to be opened to drain a little water in order to relieve some of the pressure in the storage tank.
4. The overflow pipe of the T&P valve needs to be taken off. It might have to be cut off if it is soldered or securely glued.
5. The pressure relief valve needs to be unscrewed with a pipe wrench.
6. Wrap the new T&P valve with Teflon tape and screw it in place. Ensure the overflow pipe opening is placed away from the storage tank.
7. Reattach the drain pipe, likewise utilizing brand-new Teflon tape.
8. Turn the water back on, and analyze your work for any leakages.