How to Diagnose a Leaking Douglasville Water Heater

Posted by on Apr 11, 2014 in Gas Water Heater Repair Douglasville GA, Water Heater Repair Douglasville GA | 0 comments

Definitely not something that one desires to ignore or delay, is a leaking water heater. Even if it just seems a little leak, let’s look after the problem in a timely way. Many times Water Heater Repair Douglasville GA has seen a minor leakage is an indication of a bigger problem at hand, or practically to be at hand.Water Heater Repair Douglasville GA

Aside from the possible trouble the water heater itself might be having, one will want to make sure the water leaking does not damage the floor or walls in the area of the leakage (not understanding where ones water heater is found). If that little leak becomes a major leak, the water damage can be expensive.

Also, there are wellness concerns with mold and mildew if the wet locations remain damp for a long period of time. Some mold spores can be harmful and trigger wellness worries the EPA warns.

And, we have yet to see a water heater leak go away or fix itself.

Let’s Figure Out From Where the Leak is Coming
Condensation can form in excessively moist weather condition, so a small quantity of water under or by the storage tank might not be a leakage. Various other home appliances or a furnace drain line could be the culprit even. Do an excellent investigation to be sure.

Take a look at the plumbing fittings and the top, sides and bottom of the water heater next. If they appear to be dry, that is a great sign and once more, may be originating from something else in the room. Not to be excessively obvious, however look up directly above the water on the floor and see if an overhead pipe or something else could be the cause.

Right here’s a great test to carry out next if all looks alright. Dry the puddle of water. Put some dry paper towels down on top of where the puddle was and check them periodically. If they remain dry all is well. If not and there is nothing else in the location to cause the water, then it appears like it is the water heater.

Once it is understand that the heater is leaking, the first thing to do is turn off the power. For electric heaters turn it off at the circuit breaker. For gas heaters, set the dial to off. If the leakage is substantial, certainly turn the water system off as well.

Even if one is not feeling excessively comfortable repairing the leakage oneself, by assisting locate the source of the leak will at first help the water heater repair business that will assist.

Four Locations to Check for Leaks on the Water Heater

1. First check all-time low of the tank. There is a layer of insulation and the tank really has two layers to it. An internal leak will typically appear from the bottom of the tank. If the water heater is getting older, the within will ultimately rust and weaken and will should be replaced.

2. The temperature level and pressure relief valve, or called the T&P valve. It can be discovered on the side of the tank and has actually a pipe linked to it that diminishes the side of the tank to the ground. It’s function is the release additional pressure in the water storage tank. If it is leaking, water could permeate out of it by the handle or around where it connected to the tank. Water may be diminishing the pipe it is connected to. One can repair these leaks for the valves can use out. Nonetheless, it is good to be knowledgeable about this for the function of the valve is to ensure the tank does not blow up … so it’s type of important to state the least.

One ought to a minimum of when a year raise the pressure relief valve to make certain some water will come out and stop again when the valve is released. If water still flows or for some reason the valve will not open, it requires changed.

3. Next check the drain valve. It is easy enough to do. It is found on the side to the bottom of the storage tank. It requires to be closed all the way, undoubtedly. This is an easy fix if it is leaking. Sometimes these are made from plastic and can use out. Much like checking the pressure relief valve annual, this should be opened and closed to make certain it does not close up from lake of use.

4. Finally, check the tightness of the cold and hot water connections to the water heater, found at the top. They could just have to be tightened up. If after tightening them they still reveal they are leaking, replacing the connections generally will suffice.

In future articles Water Heater Repair Douglasville GA will go into detail on how to deal with some of these repairs oneself. Let us know if you do not feel comfy dealing with any of this yourself.